Code: C-1244
Description: The saddle stitching alignment home sensor /Rt (PS28) does not turn ON within a specified period of time after the saddle stitching alignment motor / Rt (M9) starts the home position search operation. Or, even after a specified period of time after M9 starts the operation, it does not stop.
Causes: • Saddle stitching alignment motor /Rt (M9) • Saddle stitching alignment home sensor / Rt (PS28) • SD control board (SDCB) • SD drive board (SDDB) DIPSW7-0
Remedy: 1. Check the saddle stitching alignment section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. 3. Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-506: 19-D) 5. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: SD-506: 17-D) 6. Replace PS28. 7. Replace M9. 8. Replace SDDB. 9. Replace SDCB.