Code: C-1504
Description: The SC entrance conveyance has not been completed within a specified period of time after the SC entrance conveyance motor (M11) turns ON.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • SC entrance conveyance motor (M11) DIPSW7-6
Remedy: 1. Check the SC entrance conveyance section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PB-503: 4-D) 5. Replace M11. 6. Replace PBDB1. 7. Replace PBCB.