Code: C-2217
Description: Leakage at the mixing section is detected. When the toner pump motor (M28) is operating, the cup section toner remaining sensor (PS34) detects the toner being provided in succession for seconds.
Causes: • Cup section toner remaining sensor (PS34) • Toner pump motor (M28) • Printer control board (PRCB)
Remedy: 1. Check the toner mixing section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. 3. Check the sensor, and repair/replace it if any abnormality.(Wiring diagram: Main body (3/4): 7-D, 8-P) 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (3/4): 3-P) 5. Replace PS34. 6. Replace M28. 7. Replace PRCB.