Code: C-2235
Description: Transfer belt pressure release motor (M26) operation time abnormality 2.
Causes: • Transfer pressure home sensor (PS54) • Transfer belt pressure release motor (M26) • ADU drive board (ADUDB)
Remedy: 1. Check the transfer belt pressure release section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between ADUDB and motor/sensor, and repair it if any abnormality. 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: Main body (2/4): 19-J) 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (2/4): 20-P) 5. Replace PS54. 6. Replace M26. 7. Replace PRCB.