Code: C-2238
Description: Blade motor (M22) abnormality. Waste blade motor does not move to the weak pressure position within a specified period of time after M22 turns ON.
Causes: • Blade sensor /1 (PS24) • Blade sensor /2 (PS25) • Blade motor (M22) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (3/4): 14-I) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: Main body (3/4): 14-I, 15-I) 4. Replace PS24 or PS25. 5. Replace M22. 6. Replace PRCB.