Code: C-2808
Description: Dot diameter correction abnormality. While in the dot diameter correction, the correction is terminated with an abnormal value.
Causes: • Drum potential sensor (DPS) • Drum potential sensor board (DPSB) • Image processing board (IPB) • Printer control board (PRCB) • Overall control board (OACB)
Remedy: 1. Check the DPS, and clean/replace it if any abnormality or dirt on sensor (Wiring diagram: Main body (3/4): 19-J) 2. Check the connector connection and the wiring between PRCB and OACB, and repair it if any abnormality. 3. Check the connector connection and the wiring between OACB and IPB, and repair it if any abnormality. 4. Replace DPS. 5. Replace DPSB. 6. Replace IPB. 7. Replace PRCB.