Code: C-2816
Description: Drum charger capacity deterioration. When the charger grid/ developing bias is in excess of the limit of correction, lower the developing potential/ fogging margin potential in steps of 50V. As a result, less than 50V of the difference with the target charger potential is detected 10 times in succession.
Causes: • Drum potential sensor (DPS) • Drum potential sensor board (DPSB) • Charging corona • High voltage unit /1 (HV1)
Remedy: 1. Clean the power feed section for the charger. 2. Check the DPS, and clean/replace it if any abnormality or dirt on sensor (Wiring diagram: Main body (3/4): 19-J) 3. Check the charger (charging wire and the grid), and clean/repair it if there is any dirt or abnormality. 4. Check the drum, and clean/repair it if there is any dirt or abnormality. 5. Check the connector connection and the wiring between HV1 and the charger, and repair it if any abnormality. (Wiring diagram: Main body (3/4): 22-K). 6. Replace DPS. 7. Replace DPSB. 8. Replace the drum. 9. Replace HV1.