Code: C-3901
Description: Thermistor /1 (TH1) high temperature abnormality (long time/software). TH1 detects a temperature of 240°C or above 60 times in a period of 0.5second.
Causes: • Fusing temperature sensor /1 (TH1) • Fusing heater lamp /1 (L1) • Fusing heater lamp /2 (L2) • Printer control board (PRCB) • AC drive board (ACDB)
Remedy: 1. Check the fusing heater lamp /1 and /2 (L1 and L2), and clean/repair them if any abnormality. (Wiring diagram: Main body (1/4): 2-A, Main body (1/4): 3-A) 2. Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. 3. Check the connector connection and the wiring between ACDB and L1/L2, and repair it if any abnormality. 4. Check TH1 to see the installed position or distance to the fusing roller /Up, and adjust/replace it if any abnormality. (Wiring diagram: Main body (3/4): 11-I (S1/S2), 11-F (S3)). 5. Replace TH1. 6. Replace L1 and L2. 7. Replace PRCB. 8. Replace ACDB.