Mã lỗi C-C103 — Konica-Minolta bizhub PRESS 1250p

Code: C-C103

Description: Communication error between the overall control board (OACB) and the operation board /1 (OB1). Communication error from OB1 is detected. Or transmission is not completed.
Causes: • Operation board /1 (OB1) • Overall control board (OACB)
Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between OB1 and OACB, and repair it if any abnormality. (Wiring diagram: Main body (4/4): 3-D, Main body (1/4): 11-N) 3. Check the connector connection and the wiring of the operation panel, and repair it if any abnormality. 4. Replace OB1. 5. Replace OACB.