Mã lỗi SC21-04 — Konica-Minolta bizhub Pro 1050e

Code: SC21-04

Description: It is checked that the operations of the transfer/separation cleaning motor (M20) are over. • When the transfer/separation cleaning home sensor (PS38) is OFF with the main power switch (SW1) ON, the PS38 does not turn ON within a specified period of time after the transfer/ separation cleaning motor (M20) turns ON for a home position research operation (return operation). At this time, an error detection signal (blowout of a fuse) is not detected. • The PS38 does not turn OFF within a specified period of time after the reverse operation (return operation) is started. At this time, an error detection signal (blowout of a fuse) is not detected. • The transfer/separation cleaning limit sensor (PS39) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS38 being OFF. Or, the PS38 does not turn ON within a specified period of time after the PS39 turns ON. At this time, an error detection signal (blowout of a fuse) is not detected.
Causes: Transfer/separation cleaning motor (M20) Transfer/separation cleaning home sensor (PS38) Transfer/separation cleaning limit sensor (PS39) ADU drive boards /1, /2 (ADUDB/1, /2)
Remedy: The main body stops immediately to turn OFF the RL1 (main).