Code: SC21-05
Description: The blowout of a fuse for the transfer/separation cleaning motor (M20) in the ADU drive boards /1 and /2 (ADUDB/1 and /2)is checked. • When the transfer/separation cleaning home sensor (PS38) is OFF with the main power switch (SW1) ON, the PS38 does not turn ON within a specified period of time after the transfer/ separation cleaning motor (M20) turns ON for a home position research operation (return operation). At this time, an error detection signal (blowout of a fuse) is detected. • The PS38 does not turn OFF within a specified period of time after the reverse operation (return operation) is started. At this time, an error detection signal (blowout of a fuse) is detected. • The PS39 does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS38 being OFF. Or, the PS38 does not turn ON within a specified period of time after the PS39 turns ON. At this time, an error detection signal (blowout of a fuse) is detected.
Causes: Transfer/separation cleaning motor (M20) ADU drive boards /1, /2 (ADUDB/1, /2)
Remedy: The main body stops immediately to turn OFF the RL1 (main).