Code: SC46-01
Description: APC abnormality. While in the image write, the APC is not applicable for the correction of the sub scan beam. Due to the 12V DC power for the laser drive not supplied, the MPC being wrong and the laser defective, the laser does not light up. Also, due to the rotation of the polygon mirror unavailable, the displacement of the index sensor, and the index sensor being defective, the index sensor cannot detect the laser.
Causes: Write unit Power connector of the image processing board (IPB)
Remedy: If there is a copy being made, the main body completes the paper exit before stopping operations. Turn OFF the RL1 (main).