Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC21-02 — Konica-Minolta bizhub Pro 1050P

Code: SC21-02

Description: The blowout of a fuse for the charger cleaning motor (M23) in the printer control board (PRCB) is checked. • When the charger cleaning home sensor (PS26) is OFF with the main power switch (SW1) ON, the PS26 does not turn ON within 35 seconds after the M23 turns ON for home position research operation (return operation). And at this time, an error detection signal (blowout of a fuse) is detected. • The PS26 does not turn OFF within 15 seconds after the reverse operation (return operation) is started. And at this time, an error detection signal (blowout of a fuse) is detected. • The charger cleaning limit sensor (PS27) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS26 being OFF. Or, the PS26 does not turn ON within a specified period of time after the PS27 turns ON. At this time, an error detection signal (blowout of a fuse) is detected.
Causes: Charger cleaning motor (M23) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).