Code: C-0230
Description: 1st tandem PF-702/703 lower tray up abnormality. PF-702: When the upper limit sensor /3 (PS10) is OFF, PS10 does not turn ON within 20seconds after the paper lift motor /3 (M44) turns ON for lifting operation. PF-703: When the upper limit sensor /3 (PS13) is OFF, PS13 does not turn ON within 20seconds after the paper lift motor /3 (M9) turns ON for lifting operation. Or, the paper suction sensor /Fr3 and /Rr3 (PS29 and PS30) turn ON before PS13 turns ON while in tray lifting.
Causes: Upper limit sensor /3 (PS10: PF-702) Upper limit sensor /3 (PS13: PF-703) Paper lift motor /3 (M44: PF-702) Paper lift motor /3 (M9: PF-703) PF drive board (PFUDB: PF-702/703)
Remedy: 1 Check the paper loaded condition and the rear end restriction plate misaligned of the lower tray, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 4 Check I/O and the operation of the sensor, and repair it if any abnormality. PF-702: 7-C PF-703: 16-F 5 Replace PS10: PF-702 or PS13: PF-703. - 6 Replace M44: PF-702 or M9: PF703. - 7 Replace PFUDB.