Code: C-0380
Description: 2nd tandem PF-702/703 paper feed assist fan /Rr3 (FM6: PF-702, FM10: PF-703) power abnormality. The FM6EM and FM10EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM10 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: Paper feed assist fan /Rr3 (FM6: PF-703) Paper feed assist fan /Rr3 (FM10: PF-703) PF drive board (PFUDB)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 3 Replace FM6 and PFUDB at a time: PF-702 Replace FM10 and PFUDB at a time: PF-703