Code: C-0397
Description: PI-PFU (PF-703) cooling fan power abnormality. The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: PF cooling fan (FM7: PF-702) PF cooling fan/1 (FM19: PF-703) PF cooling fan /2 (FM20: PF-703) PF drive board (PFUDB)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 8-H PF-703: 22-F, 23-F 3 Replace FM7 and PFUDB at a time: PF-702 Replace FM19, FM20 and PFUDB at a time: PF-703