Code: C-0539
Description: 2nd tandem PF-703 paper suction fan /3 (FM15) power abnormality. The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: Paper suction fan /3 (FM15: PF-703) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 16-L 3 Replace FM15 and PFUDB at a time.