Code: C-0621
Description: PI-PFU (PF-703) dehumidifier fan /Rt1 (FM22) rotation abnormality. The FM22EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: Dehumidifier fan /Rt1 (FM22: HT-505) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 9-B 3 Replace the fun heater (FM22). - 4 Replace PFUDB.