Code: C-0661
Description: 2nd tandem PF-703 dehumidification heater /2 (HTR2) temperature rise abnormality. The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON.
Causes: Middle tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB.