Code: C-1106
Description: Stapler movement abnormality. The stapler movement home sensor (PS11) does not turn ON within a specified period of time after the home position search operation of the stapler movement motor (M11) starts. 35-0
Causes: Stapler movement home sensor (PS11: FS-521) Stapler movement motor (M11: FS-521) FNS drive board (FNSDB: FS-521) FNS control board (FNSCB: FS-521)
Remedy: 1 Check the stapler movement section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FS-521: 5-G 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FS-521: 2-G 6 Replace PS11. - 7 Replace M11. - 8 Replace FNSDB. - 9 Replace FNSCB. -