Code: C-1108
Description: Stapler vertical rotation abnormality. The stapler rotation home sensor (PS14) does not turn OFF within a specified period of time after the home position search operation of the stapler rotation motor (M4) starts. 35-0
Causes: Stapler rotation home sensor (PS14: FS-521) Stapler rotation motor (M4: FS-521) FNS drive board (FNSDB: FS-521) FNS control board (FNSCB: FS-521)
Remedy: 1 Check the stapler rotation section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FS-521: 5-G 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FS-521: 2-G 6 Replace PS14. - 7 Replace M4. - 8 Replace FNSDB. - 9 Replace FNSCB.