Code: C-1141
Description: Stack assist guide motor (M24) operation abnormality. After M24 starts operations, the stack assist home sensor (PS32) does not turn ON within a specified period of time. 35-1
Causes: Stack assist home sensor (PS32: FS-521) Stack assist guide motor (M24: FS-521) FNS drive board (FNSDB: FS-521) FNS control board (FNSCB: FS-521)
Remedy: 1 Check the stapler rotation section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FS-521: 5-G 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FS-521: 3-B 6 Replace PS32. - 7 Replace M24. - 8 Replace FNSDB. - 9 Replace FNSCB.