Code: C-1142
Description: Intermediate up and down roller operation abnormality. The Intermediate roller release solenoid (SD7) does not turn ON within a specified period of time after SD7 does not turn OFF within a specified period of time after the alignment motor /Fr and Rr/ (M22 and M5) turn OFF. Or, SD7 does not turn ON within a specified period of time after it turns OFF.
Causes: Intermediate roller home sensor (PS33: FS-521) Intermediate roller open close motor (M25: FS-521) FNS drive board (FNSDB: FS-521) FNS control board (FNSCB: FS-521)
Remedy: 1 Check the intermediate roller open close section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FS-521: 4-G 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FS-521: 3-G 6 Replace PS33. - 7 Replace M25. - 8 Replace FNSDB. - 9 Replace FNSCB.