Code: C-1143
Description: Conveyance operation abnormality. The conveyance motor (M1) does not turn ON when the start button is turned ON. Or the conveyance motor (M1) does not shift the speed for each processing. 35-1
Causes: Conveyance motor (M1: FS-521) FNS drive board (FNSDB: FS-521) FNS control board (FNSCB: FS-521)
Remedy: 1 Check the conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FS-521: 1-B 5 Replace M1. - 6 Replace FNSDB. - 7 Replace FNSCB.