Code: C-1146
Description: Bypass roller release motor (M12) drive abnormality. The bypass roller release home sensor (PS13) does not turn ON even after a specified period of time after M12 starts the home position search operation. Or, even after a specified period of time after M12 starts the operation, it does not stop. 35-1
Causes: Bypass roller release home sensor (PS13: FS-521) Bypass roller release motor (M12: FS-521) FNS drive board (FNSDB: FS-521) FNS control board (FNSCB: FS-521)
Remedy: 1 Check the bypass roller section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FS-521: 5-C 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FS-521: 4-B 6 Replace PS13. - 7 Replace M12. - 8 Replace FNSDB. - 9 Replace FNSCB.