Code: C-1213
Description: 2nd tandem LS-505 alignment motor (M7) drive abnormality. The alignment plate home sensor (PS12) does not turn ON within a specified period of time after M7 turns ON. Or, PS12 does not turn ON within a specified period of time. 33-7
Causes: Alignment plate home sensor (PS12: LS-505) Alignment motor (M7: LS-505) LS control board (LSCB: LS-505)
Remedy: 1 Check the alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 7-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 5-H 5 Replace PS12. - 6 Replace M7. - 7 Replace LSCB.