Code: C-1214

Description: 2nd tandem LS-505 grip conveyance motor (M4) drive abnormality. The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after M4 turns ON. 33-7
Causes: Grip conveyance home sensor (PS5: LS-505) Grip conveyance motor (M4: LS-505) LS control board (LSCB: LS-505)
Remedy: 1 Check the grip conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 6-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 2-H 5 Replace PS5. - 6 Replace M4. - 7 Replace LSCB.