Code: C-1215
Description: 2nd tandem LS-505 stacker tray upper limit abnormality. The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) is in the up operation. 33-7
Causes: Stacker tray upper limit switch (MS2: LS-505) Stacker tray up down motor (M1: LS-505) LS control board (LSCB: LS-505)
Remedy: 1 Check the stacker tray up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/switch, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 5-A 4 Check the switch operation, and repair/replace it if any abnormality. LS-505: 7-A 5 Replace MS2. - 6 Replace M1. - 7 Replace LSCB.