Code: C-1221
Description: 1st folding release motor (M14) drive abnormality. The 1st folding cam home sensor (PS55) does not turn ON within a specified period of time after M14 turns ON. 33-0
Causes: 1st folding cam home sensor (PS55: FD-503) 1st folding release motor (M14: FD-503) Folding drive board (FDB: FD-503)
Remedy: 1 Check the 1st folding section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 1-B 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 2-B 5 Replace PS55. - 6 Replace M14. - 7 Replace FDB.