Code: C-1226
Description: Punch alignment plate operation abnormality. The alignment plate home sensor (PS10) does not turn ON within a specified period of time after the alignment plate home position return operation starts. Or, after the alignment motor (M12) turns ON, the alignment plate home sensor (PS10) does not turn OFF. 33-0
Causes: Alignment plate home sensor (PS10: FD-503) Alignment motor (M12: FD-503) Punch drive board (PDB: FD-503)
Remedy: 1 Check the punch alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 3-D 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 5-D 5 Replace PS10. - 6 Replace M12. - 7 Replace PDB.