Code: C-1229
Description: Exit tray operation abnormality 2. The main tray lower limit sensor (PS22) does not turn ON within a specified period of time after the tray up down motor (M11) is in the down operation. 33-2
Causes: Main tray lower limit sensor (PS22: FD-503) Tray up down motor (M11: FS-503) Punch drive board (PDB: FD-503)
Remedy: 1 Check the punch alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 3-D 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 3-D 5 Replace PS22. - 6 Replace M11. - 7 Replace PDB.