Code: C-1242
Description: Folding main scan alignment motor /Fr (M7) drive abnormality. The folding main scan alignment home sensor /Fr1 (PS18) does not turn ON even after a specified period of time after M7 starts the home position search operation. Or, even after a specified period of time after M7 starts the operation, it does not stop. 34-0/1/2/3
Causes: Folding main scan alignment home sensor /Fr1 (PS18: SD-506) Folding main scan alignment motor /Fr (M7: SD- 506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the folding main scan alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 8-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 13-D 6 Replace PS18. - 7 Replace M7. - 8 Replace SDDB. - 9 Replace SDCB.