Code: C-1249
Description: Folding main scan alignment motor /Rr (M14) drive abnormality. The folding main scan alignment home sensor /Rr (PS19) does not turn ON even after a specified period of time after M14 starts the home position search operation. Or, even after a specified period of time after M14 starts the operation, it does not stop. 34-0/1/2/3
Causes: Folding main scan alignment home sensor /Rr (PS19: SD-506) Folding main scan alignment motor /Rr (M14: SD- 506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the folding main scan alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 11-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 12-D 6 Replace PS19. - 7 Replace M14. - 8 Replace SDDB. - 9 Replace SDCB.