Code: C-1250
Description: Stapler movement motor (M15) drive abnormality. The stapler movement home sensor (PS25) does not turn ON even after a specified period of time after M15 starts the home position search operation. Or, even after a specified period of time after M15 starts the operation, it does not stop. 34-0/1/3
Causes: Stapler movement home sensor (PS25: SD-506) Stapler movement motor (M15: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the stapler movement section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 15-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 18-D 6 Replace PS25. - 7 Replace M15. - 8 Replace SDDB. - 9 Replace SDCB. -