Code: C-1253
Description: 1st folding blade motor (M18) drive abnormality. The 1st folding blade home sensor /2 (PS21) does not turn ON even after a specified period of time after M18 starts the home position search operation. Or 1st folding blade home sensor /1 (PS20) does not turned ON within a specified period of time after M18 starts the operation. 34-0/1/2/3
Causes: 1st folding blade home sensor /1 (PS20: SD-506) 1st folding blade home sensor /2 (PS21: SD-506) 1st folding blade motor (M18: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the 1st folding section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 11-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 12-D 6 Replace PS20 or PS21. - 7 Replace M18. - 8 Replace SDDB. - 9 Replace SDCB.