Code: C-1254
Description: 2nd folding blade motor (M19) drive abnormality. The 2nd folding blade home sensor /2 (PS23) does not turn ON even after a specified period of time after M19 starts the home position search operation. Or the 2nd folding blade home sensor /1 (PS22) does not turned ON within a specified period of time after M19 starts the operation. 34-2
Causes: 2nd folding blade home sensor /1 (PS22: SD-506) 2nd folding blade home sensor /2 (PS23: SD-506) 2st folding blade motor (M19: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the 2nd folding section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 11-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 12-D,13-D 6 Replace PS22 or PS23. - 7 Replace M19. - 8 Replace SDDB. - 9 Replace SDCB.