Code: C-1257
Description: Bundle arm rotation motor (M22) drive abnormality. The bundle arm rotation home sensor (PS31) does not turn ON even after a specified period of time after M22 starts the home position search operation. Or, even after a specified period of time after M22 starts the operation, it does not stop. 34-0/1/3
Causes: Bundle arm rotation home sensor (PS31: SD-506) Bundle arm rotation motor (M22: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the bundle arm rotation section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 27-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 24-D 6 Replace PS31. - 7 Replace M22. - 8 Replace SDDB. - 9 Replace SDCB.