Code: C-1259
Description: Bundle press stage up down motor (M24) drive abnormality. The bundle press stage up down home motor (PS35) does not turn ON even after a specified period of time after M24 starts the home position search operation. Or PS35 or the bundle press stage up down upper limit sensor (PS45) does not turned ON after a specified period of time M24 starts the operation. 34-0/1/3
Causes: Bundle press stage up down home sensor (PS35: SD-506) Bundle press stage up down limit sensor (PS45: SD-506) Bundle press stage up down motor (M24: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the bundle press stage up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 21-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 24-D, 25-D 6 Replace PS35 or PS45. - 7 Replace M24. - 8 Replace SDDB. - 9 Replace SDCB.