Code: C-1264
Description: Trimmer press motor (M32) drive abnormality. Or, even after a specified period of time after M32 starts the operation, it does not stop. 34-3
Causes: Trimmer press upper limit sensor (PS52: SD-506) Trimmer press home sensor (PS53: SD-506) Trimmer press motor (M32: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the trimmer press section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 22-R 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 23-R 6 Replace PS52 or PS53. - 7 Replace M32. - 8 Replace SDDB. - 9 Replace SDCB.