Code: C-1269
Description: Folding conveyance motor (M4) rotation abnormality. Rotation abnormality detected continuously for the specified time during M4 operation. 34-0/1/2/ 3
Causes: Folding conveyance motor (M4: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the folding conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 9-D 5 Replace M4. - 6 Replace SDDB. - 7 Replace SDCB.