Code: C-1273
Description: Trimmer edge upper limit abnormality. The trimmer blade upper limit sensor (PS62) does not turn ON even after a specified period of time after the trimmer blade motor (M31) starts the home position search operation. 34-3
Causes: Trimmer completion sensor (PS62: SD-506) Trimmer blade motor (M31: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the trimmer blade upper limit, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDCB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 22-R 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 10-U 6 Replace PS62. - 7 Replace M31. - 8 Replace SDDB. - 9 Replace SDCB.