Code: C-1510
Description: Clamp entrance movement motor (M19) drive abnormality. The movement of the SC entrance has not been completed within a specified period of time after M19 turns ON. 35-4
Causes: Clamp entrance movement motor (M19: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
Remedy: 1 Check the clamp entrance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 5-D PB-503: 5-D 5 Replace M19. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.