Code: C-1549
Description: High temperature abnormality of the center of the glue tank (software detection) The glue tank temperature sensor /Md (TH3) detects an abnormal high temperature. 35-5
Causes: Glue tank temperature sensor /Md (TH3:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503)
Remedy: 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH3. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire.