Code: C-1565
Description: PB-503: Operation abnormality of the relay conveyance motor (M92) The relay conveyance does not start within the specified period of time after M92 turns ON. 35-4
Causes: Intermediate conveyance motor (M92: PB-503) PB drive board /2 (PBDB2: PB-503) PB control board (PBCB: PB-503)
Remedy: 1 Check the relay conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB2 and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-503: 23-V 4 Replace M92. - 5 Replace PBDB2. - 6 Replace PBCB.