Code: C-1566
Description: PB-503: Operation abnormality of the relay conveyance exit motor (M91) An error detection signal is detected continuously while the M91 is driving. 35-4
Causes: Relay conveyance exit motor (M91: PB-503) PB control board (PBCB: PB-503) PB drive board /1 (PBDB1: PB-503) PB drive board /2 (PBDB2: PB-503)
Remedy: 1 Check the relay conveyance paper exit section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB2 and the motor, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-503: 26-W 5 Replace M91. - 6 Replace PBDB2. - 7 Replace PBDB1. - 8 Replace PBCB. -