Code: C-2206
Description: Drum motor (M2) drive abnormality. The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected within a specified period of time after M2 turns OFF. At this time, an error detection signal is not detected.
Causes: Drum motor (M2) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 20-K 3 Replace M2. - 4 Replace PRCB.