Code: C-2231
Description: De-curler motor (M32) rotation abnormality. The M32EM error detection signal is detected twice in succession within a specified period of time after M32 was turned ON, and the main door detection is Close.
Causes: De-curler motor (M32) ADU drive board (ADUDB) Printer control board (PRCB)
Remedy: 1 Check the de-curler section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ADUDB and the motor, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 15-O 5 Replace M32. - 6 Replace PRCB.