Code: C-2234
Description: Transfer belt pressure release motor (M26) operation time abnormality 1. When M26 moves from the HP position to the pressure position, the transfer pressure position sensor /1 or /2 (PS55 or PS56) does not turn ON within a specified period of time. At this time, the main door detection is Close.
Causes: Transfer pressure position sensor /1 (PS55) Transfer pressure position sensor /2 (PS56) Transfer belt pressure release motor (M26) ADU drive board (ADUDB)
Remedy: 1 Check the transfer belt pressure release section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between ADUDB and motor/sensor, and repair it if any abnormality. - 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 19-L 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 21-L 5 Replace PS55 or PS56. - 6 Replace M26. - 7 Replace ADUDB.