Code: C-2803
Description: The IDC sensor (TCB) output abnormality. While in the maximum density correction, a patch for control is not output. (No output is made from the gamma sensor.)
Causes: Toner control board (TCB) LPH board (LPHB) Overall control board (OACB) Image processing board (IPB)
Remedy: 1 Check TCB, and clean it with alcohol if there is IDC sensor dirt or any abnormality. Be sure to clean TCB with alcohol, otherwise replacement of TCB is required. 17-F 2 Check the LPH section, and clean/replace it if there is LED dirt or any abnormality. 18-C 3 Check the connector connection and the wiring between OACB and IPB, and repair it if any abnormality. - 4 Check the connector connection and the wiring between LPHB and IPB, and repair it if any abnormality. - 5 Replace LPHB. - 6 Replace IPB. - 7 Replace OACB.