Code: C-2816
Description: Drum charger capacity deterioration. When the charger grid/developing bias is in excess of the limit of correction, lower the developing potential/fogging margin potential in steps of 50V. As a result, less than 50V of the difference with the target charger potential is detected 10 times in succession.
Causes: Drum potential sensor (DPS) Drum potential sensor board (DPSB) Charging corona High voltage unit /1 (HV1)
Remedy: 1 Clean the power feed section for the charger. - 2 Check DPS, and clean/repair it if there is sensor dirt or any abnormality. 17-F 3 Check the charger (charging wire and the grid), and clean/repair it if there is any dirt or abnormality. - 4 Check the drum, and clean/repair it if there is any dirt or abnormality. - 5 Check the connector connection and the wiring between HV1 and the charger, and repair it if any abnormality. 18-G 6 Replace DPS. - 7 Replace DPSB. - 8 Replace the drum. - 9 Replace HV1.